System One BiPAP AutoSV with Humidifier
Details
Philips Respironics BiPAP AutoSV with Heated Humidfier
Copy of RX Required if Applicable to U.S Residents
Product Description
The Philips Respironics BiPAP AutoSV Advanced System One device is intended to augment your breathing by supplying pressurized air through a circuit. It senses the your breathing effort by monitoring airflow in the circuit and adjusts its output to assist in inhalation and exhalation. This therapy is known as Bi-level ventilation. Bi-level ventilation provides a higher pressure, known as IPAP (Inspiratory Positive Airway Pressure), when you inhale, and a lower pressure, known as EPAP (Expiratory Positive Airway Pressure), when you exhale. The higher pressure makes it easier for you to inhale, and the lower pressure makes it easier for you to exhale.
When prescribed, the device can also provide features to help make your therapy more comfortable. The ramp function allows you to lower the pressure when trying to fall asleep. The air pressure will gradually increase until the prescription pressure is reached. Additionally, the Bi-Flex comfort feature provides increased pressure relief during the expiratory phase of breathing.
Special Features
Bi-Flex Comfort Feature: If enabled, the device provides a comfort feature called Bi-Flex. The Bi-Flex attribute adjusts therapy by inserting a small amount of pressure relief during the latter stages of inspiration and during active exhalation (the beginning part of exhalation). Bi-Flex levels of 1, 2, or 3 progressively reflect increased pressure relief that will take place at the end of inspiration and at the beginning of expiration.
Ramp: If enabled, the device is equipped with a linear ramp function. The Ramp feature will reduce the pressure and then gradually increase (ramp) the pressure to the prescription pressure setting so patients can fall asleep more comfortably.
Rise Time Comfort Feature: If enabled, the device provides a comfort feature called Rise Time. Rise time is the amount of time it takes the device to change from the expiratory pressure setting to the inspiratory pressure setting. Rise time levels of 0, 1, 2, or 3 progressively reflect slowed response of the pressure increase that will take place at the beginning of inspiration. A setting of 0 is the fastest rise time while a setting of 3 is the slowest. Providers should adjust the rise time to find the most comfortable setting for the patient. Rise time cannot be adjusted when Bi-Flex is enabled.
Included in This Package
- (1) System One BiPAP AutoSV
- (1) Heated Humidifier
- (1) Standard CPAP Hose
- (1) Water Chamber Tub
- (1) Set of Filters
- (1) Power Supply
- (1) Travel Case
- (1) Owners Manual
Product Specifications
- Pressure range: EPAP 4 to 25 cm H2O IPAP 4 to 25 cm H2O
- Flex pressure relief: Bi-Flex
- Ramp time: 0 to 45 min. (5-min. increments)
- Starting ramp pressure: 4 to EPAP; patient-adjustable
- Dimensions: 7" L x 5.5" W x 4" H (without humidifier) 18 cm L x 14 cm W x 10 cm H (without humidifier)
- Weight: 3.37 lbs; 1.53 kg (without humidifier)
- Filters: Foam and optional ultra-fine
- Device set-up: LCD/control wheel/push button
- Data storage capacity (minimum): Display: Compliance VIC 7- and 30-day averages SD Card: >1 year On-board: up to 6 months
- Compliance meter: Breathing detection
- Altitude compensation: Automatic
- Electrical requirements: 100 240 VAC, 50/60 Hz
- Humidification: Integrates with System One heated humidifier
- Warranty: Two years; replace with new
- Miscellaneous: Lighted LEDs
Recommended Replacement Schedule
- Filters: Every 1-3 Months (or as needed)
- Hose Tubing: Every 3-6 Months (or as needed)
- Complete Mask: Every 9-12 Months (or as needed)
- Water Chamber: Every 3-6 Months (or as needed)